恒溫(wen)恒濕試(shi)驗(yan)(yan)機是集合了高(gao)溫(wen)、低溫(wen)、濕熱為(wei)一體(ti)的試(shi)驗(yan)(yan)箱—高(gao)低溫(wen)濕熱交(jiao)變試(shi)驗(yan)(yan)箱,它的修(xiu)理難度較其它環境試(shi)驗(yan)(yan)設備(bei)大,且具(ju)有代表(biao)性。下面就高(gao)低溫(wen)濕熱交(jiao)變試(shi)驗(yan)(yan)箱為(wei)例,談(tan)一談(tan)恒溫(wen)恒濕試(shi)驗(yan)(yan)箱的構造(zao)及一些常見故障和排除方法(fa)。
一、恒溫恒濕試驗箱的構造
恒溫(wen)(wen)恒濕(shi)(shi)試驗箱(xiang)(xiang)由箱(xiang)(xiang)體、風循環系統(tong)(tong)、制(zhi)冷系統(tong)(tong)、加熱(re)系統(tong)(tong)和(he)控濕(shi)(shi)系統(tong)(tong)組成。風循環系統(tong)(tong)一般采用可調(diao)節送風方(fang)(fang)向的結(jie)構(gou)(gou);加濕(shi)(shi)系統(tong)(tong)有采用鍋(guo)爐加濕(shi)(shi)和(he)表(biao)面蒸發二種;降溫(wen)(wen)、除(chu)濕(shi)(shi)系統(tong)(tong)采用空調(diao)工況制(zhi)冷結(jie)構(gou)(gou);加熱(re)系統(tong)(tong)采用電(dian)熱(re)鰭片加熱(re)和(he)電(dian)爐絲直(zhi)接(jie)加熱(re)二種結(jie)構(gou)(gou);溫(wen)(wen)濕(shi)(shi)度(du)測試方(fang)(fang)法(fa)采用干(gan)濕(shi)(shi)球測試方(fang)(fang)法(fa),也有用濕(shi)(shi)度(du)傳感器(qi)(qi)直(zhi)接(jie)測量方(fang)(fang)法(fa);控制(zhi)和(he)顯(xian)示操作界面采用溫(wen)(wen)濕(shi)(shi)度(du)分開(kai)獨立和(he)溫(wen)(wen)濕(shi)(shi)度(du)組合控制(zhi)器(qi)(qi)等方(fang)(fang)式。
二、恒溫恒濕試驗箱的一些常見故障和排除方法
◆在高溫(wen)(wen)試驗中,如(ru)(ru)(ru)溫(wen)(wen)度(du)(du)變化達不到試驗溫(wen)(wen)度(du)(du)值(zhi)時,可以檢查(cha)電器(qi)系統,逐(zhu)一(yi)排除(chu)故障。如(ru)(ru)(ru)溫(wen)(wen)度(du)(du)升(sheng)得(de)很(hen)慢,就要(yao)查(cha)看(kan)風(feng)(feng)循環系統,看(kan)一(yi)下風(feng)(feng)循環的(de)調節擋板是(shi)否開啟正常,反之,就檢查(cha)風(feng)(feng)循環的(de)電機(ji)運轉是(shi)否正常。如(ru)(ru)(ru)溫(wen)(wen)度(du)(du)過(guo)沖厲害那么就需要(yao)整定PID的(de)設置參數。如(ru)(ru)(ru)果溫(wen)(wen)度(du)(du)直(zhi)接上升(sheng),過(guo)溫(wen)(wen)保護(hu),那么,控制器(qi)出故障,須更換控制儀(yi)表。
◆低溫(wen)達不(bu)到試驗的(de)(de)指標,那(nei)你就要(yao)(yao)(yao)觀察(cha)溫(wen)度的(de)(de)變化,是溫(wen)度降(jiang)的(de)(de)很(hen)慢,還是溫(wen)度到一定值后(hou)(hou)溫(wen)度有回升的(de)(de)趨勢,前(qian)者就要(yao)(yao)(yao)檢查一下,做低溫(wen)試驗前(qian)是否(fou)將工作(zuo)(zuo)室(shi)(shi)烘干(gan),使工作(zuo)(zuo)室(shi)(shi)保持干(gan)燥后(hou)(hou)再將試驗樣(yang)品放(fang)入工作(zuo)(zuo)室(shi)(shi)內(nei)再做試驗,工作(zuo)(zuo)室(shi)(shi)內(nei)的(de)(de)試驗樣(yang)品是否(fou)放(fang)置的(de)(de)過多,使工作(zuo)(zuo)室(shi)(shi)內(nei)的(de)(de)風不(bu)能充分循環,在排(pai)除上述原因后(hou)(hou),就要(yao)(yao)(yao)考慮是否(fou)是制(zhi)冷系(xi)統中的(de)(de)故障(zhang)了,這樣(yang)就要(yao)(yao)(yao)請廠家(jia)的(de)(de)專業人員進行檢修。后(hou)(hou)者的(de)(de)現象(xiang)是設備(bei)(bei)的(de)(de)使用環境不(bu)好所致,設備(bei)(bei)放(fang)置的(de)(de)環境溫(wen)度,放(fang)置的(de)(de)位置(箱體(ti)后(hou)(hou)與墻的(de)(de)距離)要(yao)(yao)(yao)滿足要(yao)(yao)(yao)求(qiu)(在設備(bei)(bei)操(cao)作(zuo)(zuo)使用說明中都有規(gui)定)。
◆在做濕(shi)熱試(shi)驗中,出現(xian)(xian)實際(ji)濕(shi)度(du)會(hui)達到或(huo)者實際(ji)濕(shi)度(du)與目標濕(shi)度(du)相差很大,數值低得(de)很多,前者的(de)現(xian)(xian)象:可能是(shi)(shi)(shi)濕(shi)球傳感器(qi)(qi)上的(de)紗布干燥(zao)引起,那就(jiu)要(yao)檢查濕(shi)球傳感器(qi)(qi)的(de)水(shui)(shui)槽(cao)中是(shi)(shi)(shi)否缺水(shui)(shui),水(shui)(shui)槽(cao)中的(de)水(shui)(shui)位(wei)是(shi)(shi)(shi)由一(yi)水(shui)(shui)位(wei)控制(zhi)器(qi)(qi)自動(dong)控制(zhi)的(de),查水(shui)(shui)位(wei)控制(zhi)器(qi)(qi)供(gong)水(shui)(shui)系(xi)統(tong)是(shi)(shi)(shi)否供(gong)水(shui)(shui)正(zheng)(zheng)常(chang)(chang)(chang),水(shui)(shui)位(wei)控制(zhi)器(qi)(qi)工(gong)作(zuo)(zuo)是(shi)(shi)(shi)否正(zheng)(zheng)常(chang)(chang)(chang)。另一(yi)種(zhong)可能就(jiu)是(shi)(shi)(shi)濕(shi)球紗布因使(shi)用時間(jian)長(chang),或(huo)供(gong)水(shui)(shui)水(shui)(shui)質純凈度(du)的(de)原因,會(hui)使(shi)紗布變硬(ying),使(shi)紗布無法吸收水(shui)(shui)份而干燥(zao),只要(yao)更換或(huo)清洗紗布即可排除以上現(xian)(xian)象。后者的(de)現(xian)(xian)象主(zhu)要(yao)是(shi)(shi)(shi)加(jia)濕(shi)系(xi)統(tong)不工(gong)作(zuo)(zuo),查看加(jia)濕(shi)系(xi)統(tong)的(de)供(gong)水(shui)(shui)系(xi)統(tong),供(gong)水(shui)(shui)系(xi)統(tong)內(nei)(nei)是(shi)(shi)(shi)否有一(yi)定(ding)的(de)水(shui)(shui)量,控制(zhi)加(jia)濕(shi)鍋爐水(shui)(shui)位(wei)的(de)水(shui)(shui)位(wei)控制(zhi)是(shi)(shi)(shi)否正(zheng)(zheng)常(chang)(chang)(chang),加(jia)濕(shi)鍋爐內(nei)(nei)的(de)水(shui)(shui)位(wei)是(shi)(shi)(shi)否正(zheng)(zheng)常(chang)(chang)(chang)。如以上一(yi)切都正(zheng)(zheng)常(chang)(chang)(chang),那就(jiu)要(yao)檢查電器(qi)(qi)控制(zhi)系(xi)統(tong),這要(yao)請(qing)專業維修人員進(jin)行檢修。
◆設(she)備(bei)在試驗(yan)運(yun)行過(guo)程中突然出現故障(zhang)時,控制儀表上出現對(dui)(dui)應的(de)(de)故障(zhang)顯示提(ti)示并有聲訊報警提(ti)示。操作(zuo)人員可以對(dui)(dui)照(zhao)設(she)備(bei)的(de)(de)操作(zuo)使用中的(de)(de)故障(zhang)排除(chu)一(yi)(yi)章(zhang)中快速檢(jian)查出屬于哪(na)一(yi)(yi)類故障(zhang),即可請專業人員快速排除(chu)故障(zhang),以確保試驗(yan)的(de)(de)正常進行。其它環境試驗(yan)設(she)備(bei)在使用中還會有其它的(de)(de)現象,那(nei)就要具(ju)體現象,具(ju)體分析和排除(chu)。
高低溫(wen)(wen)試(shi)驗箱 或恒溫(wen)(wen)恒濕試(shi)驗箱還要(yao)定期進(jin)行維護(hu)(hu)保養(yang),制(zhi)冷系統的冷凝器定期清理(li),對于活動(dong)部(bu)件應按說明(ming)書加油潤滑,電器控制(zhi)系統定期維護(hu)(hu)檢查等等,這些工作是(shi)*的。